Description
- Capacity (Emax) 10,20,30,40,50,60t.
- Output Digital 1,000,000 d.
- Accuracy 3C OIML R60.
- Alloy Steel and Stainless steel
- Execution Standard GB/T 7551-2008 Certificate Combined Error 0.015%
- Protection Grade IP67 And IP68
- Protection against total immersion in water for 30 min at a pressure corresponding to to 1m head of water.
Download PDF
Specification:
Item/Parameter | C4 | Unit |
---|---|---|
Rated Load | 10,20,30,40,50,60 | t |
Maximum Number Of Load Cell Verification Intervals | 3000 | d |
Minimum Number Of Load Cell Verification Intervals | 0.01 | % of rated load |
Rated Output | 30,000 to 1,00000 | d |
Combined Error | 0.015 | ± % of rated output |
Temperature effect on Sensitivity | 0.0012 | ± % of rated output |
Temperature effect on Zero Balance | 0.0008 | ± % of rated output |
Zero Balance | 1 | ± % of rated output |
Measuring Rate | 50/25 | /sec |
Baudrate | 9600/19200 | BPS |
Filter mode 1 | 3 ~ 0.05 (Low Pass filter) | Hz |
Filter Mode 0 | 3 ~ 8 (Low Pass Filter) | Hz |
Maximum Transmission distance | 1200 | m |
Save overload | 150 | % of rated capacity |
Ultimate overload | 300 | %of rated capacity |
Operating Temperature range | -20 ~ +70 / -20 ~ +160 | t/F |
Recommended excitation | 8 ~ 15 | V |
Maximum excitation | 24 | V |
Material of elastomer | Alloy Steel /Stainless Steel | |
Protection Class | IP67/IP68 | |